LK Systems Our websites English
Close

Our websites

LKS0046
LKS0046
LKS0046

LK Manifold RF

LK Manifold RF is made of stainless steel, the variants having 1 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on the supply and return, manual a...

LKS0046

LK Manifold RF

Variants

Article Length Height Depth No. of circuits CO₂-EQ. (Kg) Weight (kg) Packaging Item List
241 02 58 128 mm 355 mm 90 mm 1 3.73 1,2
241 93 50 220 mm 355 mm 90 mm 2 6.64 2,2
241 93 51 270 mm 355 mm 90 mm 3 8.22 2,4
241 93 52 320 mm 355 mm 90 mm 4 9.76 2,6
241 93 53 385 mm 355 mm 90 mm 5 11.34 2,9
241 93 54 420 mm 355 mm 90 mm 6 12.88 3,0
241 93 55 470 mm 355 mm 90 mm 7 14.46 3,2
241 93 57 520 mm 355 mm 90 mm 8 16.04 3,4
241 93 58 570 mm 355 mm 90 mm 9 17.58 3,65
241 93 59 620 mm 355 mm 90 mm 10 19.12 3,8
241 93 60 670 mm 355 mm 90 mm 11 20.7 4,0
241 93 61 720 mm 355 mm 90 mm 12 22.23 4,2

241 02 58

Length 128 mm
Height 355 mm
Depth 90 mm
No. of circuits 1
CO₂-EQ. (Kg) 3.73
Weight (kg) 1,2
Packaging
Item list

241 93 50

Length 220 mm
Height 355 mm
Depth 90 mm
No. of circuits 2
CO₂-EQ. (Kg) 6.64
Weight (kg) 2,2
Packaging
Item list

241 93 51

Length 270 mm
Height 355 mm
Depth 90 mm
No. of circuits 3
CO₂-EQ. (Kg) 8.22
Weight (kg) 2,4
Packaging
Item list

241 93 52

Length 320 mm
Height 355 mm
Depth 90 mm
No. of circuits 4
CO₂-EQ. (Kg) 9.76
Weight (kg) 2,6
Packaging
Item list

241 93 53

Length 385 mm
Height 355 mm
Depth 90 mm
No. of circuits 5
CO₂-EQ. (Kg) 11.34
Weight (kg) 2,9
Packaging
Item list

241 93 54

Length 420 mm
Height 355 mm
Depth 90 mm
No. of circuits 6
CO₂-EQ. (Kg) 12.88
Weight (kg) 3,0
Packaging
Item list

241 93 55

Length 470 mm
Height 355 mm
Depth 90 mm
No. of circuits 7
CO₂-EQ. (Kg) 14.46
Weight (kg) 3,2
Packaging
Item list

241 93 57

Length 520 mm
Height 355 mm
Depth 90 mm
No. of circuits 8
CO₂-EQ. (Kg) 16.04
Weight (kg) 3,4
Packaging
Item list

241 93 58

Length 570 mm
Height 355 mm
Depth 90 mm
No. of circuits 9
CO₂-EQ. (Kg) 17.58
Weight (kg) 3,65
Packaging
Item list

241 93 59

Length 620 mm
Height 355 mm
Depth 90 mm
No. of circuits 10
CO₂-EQ. (Kg) 19.12
Weight (kg) 3,8
Packaging
Item list

241 93 60

Length 670 mm
Height 355 mm
Depth 90 mm
No. of circuits 11
CO₂-EQ. (Kg) 20.7
Weight (kg) 4,0
Packaging
Item list

241 93 61

Length 720 mm
Height 355 mm
Depth 90 mm
No. of circuits 12
CO₂-EQ. (Kg) 22.23
Weight (kg) 4,2
Packaging
Item list

Detailed Information

Description

LK Manifold RF is made of stainless steel, the variants having 1 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on the supply and return, manual air-bleed valves and filling/drain valves*.
(*Manifold RF 1 is supplied without thermometer or filling/drain valve)

The upper manifold marked FLOW (supply) is fitted with flow indicators graded from 0,5-5 l/min and adjustment valves for the adjustment of individual circuit flows. The flow indicators are made of temperature and impact resistant plastic.
The lower manifold marked RETURN has hand actuators for shutting off individual circuits.
The manifold is ready to be connected to the left-hand side on delivery. Connection from the right is done by removing the end cap assemblies. Marking plates for identifying individual floor heating circuits, assembly instructions and a protective bag used to protect the manifold from e.g. splashes of concrete during the assembly period are enclosed.

The manifold requires additionally:
Two LK Ball Valves (Art. no. 241 75 50) or LK Ball Valve Angle (Art. no. 241 79 58). Where appropriate, the ball valve is replaced by LK OptiFlow EVO II. See product range for LK Adjustment Valves.
LK Connection Coupling for pipe range dim: PE-X/PAL pipe in dim 16 (Art. no. 241 72 98) / PE-X pipe in dim 12x2 (Art. no. 241 94 66 ) / PE-X pipe in dim 20x2 (Art. no. 241 94 68).

Connection dimensions:
Connection feed pipe, 1" female
Connection under floor heating pipe, ¾" male Eurocone

Dimensions:
The dimensions of the manifold are listed in the table below. Center dimension pipe connections is 50 mm with 25 mm displacement between flow and return. Additional length for accessories are stated below.

LK Ball Valve Straight: 65 mm
LK Ball Valve Angle: 70 mm
LK By-Pass RF: 15 mm
LK By-Pass Delta P RF: 155 mm
LK OptiFlow EVO II incl joint nipple straight: 123 mm
LK OptiFlow EVO II incl joint nipple elbow: 93 mm

Related Products

Accessories

LK Manifold RF

LK Manifold RF

LK Manifold RF is made of stainless steel, the variants having 1 to 12 floor heating circuits. The m...

LK Connection Coupling RF

LK Connection Coupling RF

For connection to LK Manifold RF. For connection of 8 mm floor heating pipes use LK PushFit 8. See ...

LK Connection Coupling

LK Connection Coupling

For connection of LK Floor Heating Pipe dim 12 mm and 16 mm, and LK Universal Pipe dim 16 mm to LK M...

LK Connection Coupling

LK Connection Coupling

For connecting the LK Universal Pipe to the LK Manifold UNI. Art. no. 481 43 73 is also intended for...

LK Connection Coupling RF

LK Connection Coupling RF

For connection of LK Under Floor Heating Pipe PE-X dim 20 to LK Manifold RF.

LK Press Connection RF

LK Press Connection RF

For connection of LK PE-X and LK PAL Universal pipe dim.16x2,0/2,2 mm and LK PE-X Heating pipe dim 2...

LK PressPex Press Connection

LK PressPex Press Connection

PressPex fitting with loose nut for connecting LK PE-X and PAL Universal pipe to male EuroCone on e....

LK Manifold Screw Plug

LK Manifold Screw Plug

Manifold screw plug with gasket to plug up unused connections on LK Manifold RF.

LK Manifold Screw Plug

LK Manifold Screw Plug

Manifold screw plug with gasket to plug up unused connections on LK Mini Manifold/LK Manifold RF. A...

LK Cap

LK Cap

Supplied complete with seal for plugging unused connections on LK Manifold UNI. For ½" and ¾" sizes,...

LK By-Pass RF

LK By-Pass RF

Complete set for assembly of by-pass with kvs 0,05 on LK Manifold RF. The by-pass extends installed ...

LK By-Pass Delta P RF

LK By-Pass Delta P RF

LK By-pass Delta P RF is a pressure controlled by-pass valve. The by-pass valve is adapted for easy ...

LK Ball Valve straight 1"

LK Ball Valve straight 1"

Isolation valve for LK Manifold RF.

LK Ball Valve angle 1"

LK Ball Valve angle 1"

Isolation valve for LK Manifold RF.

LK Connection Set straight

LK Connection Set straight

Connection Set for connection of feed pipe PE-X to LK Manifold RF.

LK Coupling male thread

LK Coupling male thread

Transitional coupling for LK Heating pipe PE-X dim 20, 25 and 32 mm.

LK Coupling male thread

LK Coupling male thread

Straight coupling with male thread for PE/PE-X pipes.

LK Connection Set angle

LK Connection Set angle

Connection Set for connection of feed pipe PE-X to LK Manifold RF.

LK Joint Nipple straight

LK Joint Nipple straight

For contraction of LK Manifold RF.

LK Joint Nipple

LK Joint Nipple

For joining LK Manifold RF/LK Mini Manifold.

LK Adapter

LK Adapter

LK Adapter with loose nut for transition from ½” to ¾” EuroCone. Fits e.g. LK Manifold RF, LK Mini L...

LK Connection Coupling RF CU

LK Connection Coupling RF CU

LK Connection coupling for copper pipes to LK Manifold RF.

LK Connection Coupling RF CU

LK Connection Coupling RF CU

LK Connection coupling RF CU for primary connection to LK Minishunt M60 manufactured after September...

LK PushFit 8, Duo

LK PushFit 8, Duo

LK PushFit to 8 mm floor heating pipe. E.g. used to connect to LK Manifold RF or LK Mini Loop Valve ...

LK PushFit 8, Quattro

LK PushFit 8, Quattro

LK PushFit to 8 mm floor heating pipe. E.g. used to connect to LK Manifold RF or LK Mini Loop Valve ...

LK Valve kit VKF RF

LK Valve kit VKF RF

LK Valve kit VKF RF is used when you need to expand an existing manifold to include another floor he...

LK Fitting Wrench

LK Fitting Wrench

LK Fitting Wrench is a circular ratchet spanner for easy assembly of connection couplings. The spann...

LK Automatic Air Vent RF

LK Automatic Air Vent RF

Intended for LK Manifold RF. Replaces the standard manual air vent. The air vent has both a manual a...

LK OptiFlow EVO II

LK OptiFlow EVO II

LK OptiFlow EVO II is a group valve for adjusting flow in, for example, under floor heating systems,...

LK Key set flow indicator, Manifold RF

LK Key set flow indicator, Manifold RF

Used to replace glass on flow indicator.

Spare Parts

Intended for